Conductivity electrode LF 435ST -5...+80°C, length 120mm, dia. 12mm
Conductivity measuring cells
With plastic shaft and internal temperature sensor NTC30 kOhm, temperature range -5 to +80 °C. Cable with 8-pole plug.
- Excellent linearity over a wide measuring range, especially for high conductivity values
- Easy cleaning
- Long term stable cell constant through abrasion resistant, concentric graphite electrodes
- Integrated temperature sensor with short response time for automatic temperature compensation
LF 435 T: Conductivity measuring cells with 4 electrode technique for a large measuring range of 5 µS/cm to 500 mS/cm, low maintanance and easy cleaning. For general measurements. With 1.5 m cable.
LF 513 T: For field and laboratory measurments of 1µS/cm to 200 mS/cm. 2 electrode measuring technique with platinized ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
LF 613 T: For field and laboratory measurments in a measuring range of 1µS/cm to 2000 mS/cm. Less polarisation effects through 4 electrode measuring technique with platinum ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
Conductivity measuring cells
With plastic shaft and internal temperature sensor NTC30 kOhm, temperature range -5 to +80 °C. Cable with 8-pole plug.
- Excellent linearity over a wide measuring range, especially for high conductivity values
- Easy cleaning
- Long term stable cell constant through abrasion resistant, concentric graphite electrodes
- Integrated temperature sensor with short response time for automatic temperature compensation
LF 435 T: Conductivity measuring cells with 4 electrode technique for a large measuring range of 5 µS/cm to 500 mS/cm, low maintanance and easy cleaning. For general measurements. With 1.5 m cable.
LF 513 T: For field and laboratory measurments of 1µS/cm to 200 mS/cm. 2 electrode measuring technique with platinized ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
LF 613 T: For field and laboratory measurments in a measuring range of 1µS/cm to 2000 mS/cm. Less polarisation effects through 4 electrode measuring technique with platinum ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
Specification
Conductivity measuring cells
With plastic shaft and internal temperature sensor NTC30 kOhm, temperature range -5 to +80 °C. Cable with 8-pole plug.
LF 435 T: Conductivity measuring cells with 4 electrode technique for a large measuring range of 5 µS/cm to 500 mS/cm, low maintanance and easy cleaning. For general measurements. With 1.5 m cable.
-Excellent linearity over a wide measuring range, especially for high conductivity values
-Easy cleaning
-Long term stable cell constant through abrasion resistant, concentric graphite electrodes
-Integrated temperature sensor with short response time for automatic temperature compensation
LF 513 T: For field and laboratory measurments of 1µS/cm to 200 mS/cm. 2 electrode measuring technique with platinized ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
LF 613 T: For field and laboratory measurments in a measuring range of 1µS/cm to 2000 mS/cm. Less polarisation effects through 4 electrode measuring technique with platinum ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
Product Specification:
Product Type: LF 435 T
Electrode: graphite
Shaft diameter: 12 mm
Length: 120 mm
Cell constant: K=0.33
With plastic shaft and internal temperature sensor NTC30 kOhm, temperature range -5 to +80 °C. Cable with 8-pole plug.
LF 435 T: Conductivity measuring cells with 4 electrode technique for a large measuring range of 5 µS/cm to 500 mS/cm, low maintanance and easy cleaning. For general measurements. With 1.5 m cable.
-Excellent linearity over a wide measuring range, especially for high conductivity values
-Easy cleaning
-Long term stable cell constant through abrasion resistant, concentric graphite electrodes
-Integrated temperature sensor with short response time for automatic temperature compensation
LF 513 T: For field and laboratory measurments of 1µS/cm to 200 mS/cm. 2 electrode measuring technique with platinized ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
LF 613 T: For field and laboratory measurments in a measuring range of 1µS/cm to 2000 mS/cm. Less polarisation effects through 4 electrode measuring technique with platinum ring electrodes. Easy cleaning through removable low shaft ending. With 1 m cable.
Product Specification:
Product Type: LF 435 T
Electrode: graphite
Shaft diameter: 12 mm
Length: 120 mm
Cell constant: K=0.33