Your basket is empty
BROWSE OUR PRODUCT CATALOGUE

BOD measuring system OxiTop®-IDS for determination of aerobic degradation, Set A6

These tests quantify the biological degradability of chemicals.
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.

  • Respirometric degradability tests according to OECD 301F/DIN EN ISO 9408
  • Versatile measurement by using the BOD special mode
  • Measurement duration selectable (0.5 hours to 180 days)
  • Bluetooth® connectivity
  • Direct calculation of all results in the meter
  • Representation of curves for monitoring
  • Parallel measurement of different examinations and methods
  • Export to data acquisition programs


Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.
Scope of supply: 6 x OxiTop®-IDS measuring heads, 6 x bottles PF45/1000 (1000 ml), 6 x adapter OxiTop® AD/SK, nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, stirring platform IS 6-Var

BOD measuring system OxiTop®-IDS for determination of aerobic degradation, Set A6

BOD measuring system OxiTop®-IDS for determination of aerobic degradation, Set A6



OxiTop-IDS A6 Xylem 209721
PART NO.4AJ-6314042
81119||82056||78951||81520||79744||81729||79823||81638||82119||81109||79504||81275||81660||81768||81348||79719||79640||81498||79556||79404||79925||81657
Type||No. of measuring positions||Min. pressure hPa||Max. pressure hPa||Pressure||Min. measured value mg/l||Max. measured value mg/l||Measured range||Measuring time d||Nominal volume bottle ml||Width||Depth||Height||Dimensions (WxDxH)||Weight||Plug type||Type of auxiliary energy||Battery/rechargeable battery||Power supply||IP code||Warranty||PK
OxiTop®-IDS A6||6||500||1250||500 ... 1,250 hPa|| ||4000||0 ... 4,000 mg/l||180||1000|| || || || || || ||Battery/mains connection|| ||100 ... 240 V, 50/60 Hz|| || ||1
Xylem
209721

BOD measurement systems

0